DRAW Administrator Guide
Isometric Automatic Drawing Production
:
Project Set-up
: Update the HVAC Catalogue (MAS)
Update the HVAC Catalogue (MAS)
Updates the HVAC catalogue if the AVEVA MAS project is being used.
Launch
AVEVA Catalogue
™
, as a user that has permissions to modify the catalogue and open the
Command Window
.
Input the command:
$M %PMLLIB%\isometricadp\data\Hvac_Paragon.dat
Close the
Command Window
and close
AVEVA Catalogue
™
.
Drawing Number
Sets the Drawing Number for each Isometric Drawing.
The drawing number can be set using the following methods:
•
Defaults File
•
Name Sequence Database
Defaults File
If the defaults file is issued, all users must have read/write access to the defaults file:
%AVEVA_DESIGN_DFLTS%\isoadp\DRA-ISO-DRWGNUMBER
Refer to
Drawing Number
for further information.
Name Sequence Database
Extracts the Drawing Number for each Isometric Drawing with the use of a Name Sequence database. The Drafting MDB must contain a Name Sequence database available in read-write mode.
When using AVEVA E3D™, this means that you must modify the module definition for DRAW to open DESI databases in read-write mode. The database containing the Link World is the only database open in write mode and therefore access to it must be controlled.
1974 to current year.