Click Reset to revert the
Supports Compensation Sizes window to the default values/settings.
Changes made are only applied to the database when Apply is clicked. To keep the changes the
Save Work operation must be performed.
Click Cancel to close the window. If changes have been made, but not applied, a window displays asking if the changes are to be applied before exiting.
The Supports Compensation Sizes window contains two tabs for specifying separate rules to calculate the X and Y sizes of the compensating plate.
The General Rule is used when a rule for a given support type is not defined.
The Default Value field defines the default X and Y sizes of the compensating plate.
You can populate the Support Codes and
X-Size Rule or
Y-Size Rule fields with the relevant rule values.
Click OK to add the rule to the list of available rules or
Cancel to discard any changes and close the
Add Entry window.
Click Remove Entry to delete the currently selected rule.