The Selection Configuration tab contains checks and restrictions for each ancillary.
The Common part of the
Selection Configuration tab applies to all ancillaries. The
Trunnion Ancillary part of the tab applies only to trunnion ancillaries and becomes active if the support class of the selected ancillary contains the word TRUNNION.
Select the Vertical check box to define that the ancillary can be created on a vertical pipe.
Select the Horizontal check box to define that the ancillary can be created on a horizontal pipe. If the ancillary is allowed on a horizontal pipe, it must pass the maximum slope check.
Select the Ignore Max Pipe Slope check box to define that the ancillary can be created on a pipe with a slope value greater than the defined maximum pipe slope in the Supports application defaults. Refer to
Max. Pipe Slope for further information.
The Head option button indicates that the trunnion ancillary is positioned on the head of the trunnion.
The Base option button indicates that the trunnion ancillary is positioned on the base of the trunnion.
The Head Components Allowed part of the tab applies only to trunnion ancillaries and becomes active if the selected ancillary is a trunnion head component.
Select the Tube check box to define that the head component of the trunnion ancillary can be positioned on a pipe tube.
Select the Elbow check box to define that the head component of the trunnion ancillary can be positioned on an pipe elbow.
Select the Reducer check box to define that the head component of the trunnion ancillary can be positioned on a pipe reducer.
Select the Tee check box to define that the head component of the trunnion ancillary can be positioned on a pipe tee.