Catalogues and Specifications
Reference Manual
Typical Specifications
:
Selectors and Pointers for Structural Components
: Examples From Structural Component Specifications
Examples From Structural Component Specifications
The following excerpt from a Specification for structural steelwork components illustrates some of the features defined in the preceding sections:
Note:
The Reference Pointers DETAIL, MATXT, CMPREF and BLTREF have been omitted to save space. Although these are available to give consistency with Piping Specifications, you are unlikely to use these for structural components (BLTREF, in particular, would have no meaning for a structural component). No defaults have been set in this example.
NEW SPECIFICATION /BS4.PT1
MATREF =0
FLUREF =0
RATING 0.000
LINETYPE NUL
TEXT ’Middlesbrough Mills’
HEADING
TYPE NAME STYP GRADE WIDTH DEPTH WEIGHT INERTIA CATREF
BEAM */UB1 UB 43 465 153 82 32435 /457X152X82UB
+ */UB2 + 50 465 153 82 32435 /457X152X82UB
+ */UB3 + 43 310 125 48 9504 /305X127X48UB
...
HEADING
TYPE NAME STYP GRADE DEPTH WIDTH WEIGHT INERTIA CATREF
BRAC */UEA1 UEAM 43 200 150 47 2376 /200X150X18L
+ */UEA2 + 50 200 150 47 2376 /200X150X18L
+ */UEA3 + 43 125 75 18 354 /125X75X12L
...
HEADING
TYPE NAME STYP WIDTH DEPTH WEIGHT INER1 INER2 CATREF
PROF */BS.C1 C 102.0 432.0 65.5 21399.0 628.6 /432X102X65KG.C
+ */BS.C2 + 102.0 381.0 55.1 14894.0 579.8 /381X102X55KG.C
...
PROF */BS.CRSJ1 CRSJ 102.0 305.0 25.3 5372.0 162.5 /305X102X25KG.CRSJ
+ */BS.CRSJ2 + 102.0 267.0 21.5 3562.0 139.1 /267X102X21KG.CRSJ
HEADING
TYPE NAME STYP DEPT WIDT WEIG INER1 INER2 CATREF
PROF */BS.CUB1 CUB 1371.0 419.0 388.0 1661103.0 42443.0 /1371X419X388KG.CUB
+ */BS.CUB2 CUB 1371.0 419.0 343.0 1449837.0 36223.0 /1371X419X343KG.CUB
...
and so on.
1974 to current year.