Bocad Steel Interface
Bocad Steel Interface
:
Supplementary Information
: Catalogue Versions
Catalogue Versions
During the lifetime of this application, updates to the Catalogue are quite likely. For example a typical change might be the default orientation of an unequal angle. This has been a cause of problems in the past when operating the application on both PDMS12.1 and AVEVA E3D 2.1™.
You can perform a quick check to validate the profile orientation using the following lines either in the command window or as a macro.
NEW SITE /TestAngleOri
NEW ZONE
NEW STRU
NEW FRMW
NEW GENSEC SPRE /L100x50x10
JUSL SNFG
NEW SPINE
NEW POINSP at E0
NEW POINSP at E500
Obviously you should change the SPRE to be the profile under investigation. By comparing the view between versions you can see if there is any difference in configuration between versions.
You must be aware that the Catalogue update function might need to be changed to locate the Plines correctly according to the Cardinal Points. Refer to
Cardinal Points
for more information.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.